Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Indian Heart J ; 2022 Apr; 74(2): 81-85
Article | IMSEAR | ID: sea-220873

ABSTRACT

Stress electrocardiography (sECG) or treadmill stress testing is a well validated noninvasive diagnostic modality available to clinicians at low cost yet providing valuable functional data for coronary artery disease (CAD) diagnostic and prognostic evaluation. With the advances in cardiac imaging in both functional and anatomic fronts and the existing limitations of sECG testing, this modality appears less favored worldwide as reflected in some recent guideline updates. We review the past present and future of sECG to provide a viewpoint on where it stands in CAD evaluation and if it will remain relevant as a diagnostic modality or be retired going forward. We also provide our perspectives on how sECG can co-exist with other modalities such as calcium scoring and discuss the role of such testing in the Indian population.

2.
Rev. chil. infectol ; 38(2): 260-270, abr. 2021. ilus, tab
Article in Spanish | LILACS | ID: biblio-1388227

ABSTRACT

Resumen La endocarditis infecciosa (EI) es una enfermedad de alta mortalidad, caracterizada por una infección endocárdica y frecuentes complicaciones multiorgánicas, que requiere un diagnóstico rápido y preciso, y un manejo agresivo, ya sea médico o quirúrgico. Su diagnóstico se realiza tomando en cuenta criterios bacteriológicos, clínicos y ecocardiográficos. Es objetivo de este artículo realizar una actualización del estudio imagenológico en paciente con EI, con especial énfasis en aquellos exámenes no ecocardiográficos disponibles en nuestro medio. En los últimos años, estudios de imagen avanzados han adquirido un rol creciente en su estudio inicial, particularmente la tomografía computada multicorte (TCMC) cardiaca y el positron emission tomography/computed tomography (PET/CT), y han sido recomendados como criterios diagnósticos en las guías recientes para el manejo de esta entidad. La TCMC cardiaca proporciona información anatómica detallada de las válvulas cardiacas y tejido perivalvular, identificando pseudoaneurismas, abscesos y dehiscencias valvulares. El PET/CT con F18-fluorodeoxiglucosa (F18-FDG) permite aumentar la sensibilidad en la detección de EI, y pesquisar con alta eficiencia fenómenos embólicos sistémicos, de elevada frecuencia en esta población. Ambos métodos prestan particular utilidad en EI de válvula protésica, donde la ecocardiografía presenta menor rendimiento diagnóstico. La resonancia magnética (RM) cerebral es el mejor método de imagen para descartar eventos isquémicos/embólicos del sistema nervioso central.


Abstract Infective endocarditis (IE) is an entity characterized by endocardial infection and frequent multiorgan complications, resulting in high mortality. It requires a rapid and accurate diagnosis, and a medical or surgical aggressive treatment. Currently, IE diagnosis rests on bacterial, clinical and ultrasonographic criteria. The objective of this article is to update the imaging study in patients with IE, with special emphasis on those non-echocardiographic examinations available in our environment. Last years, advanced imaging had achieved a growing role in IE diagnosis, especially cardiac multislice computed tomography (MSCT) and positron emission tomography/computed tomography (PET/CT), which have been recommended in recent clinical guidelines to be included as part of diagnostic criteria. Cardiac MSCT provides detailed anatomic information of cardiac valves and perivalve tissue, allowing identification of pseudoaneurysm, abscess and valve dehiscence. F18-FDG PET/CT increases sensitivity for IE detection and shows high accuracy in searching for extracranial systemic embolic events. Both MSCT and PET/CT have particular utility in cases of prosthetic valve endocarditis, where cardiac ultrasonography shows lower performance. Brain magnetic resonance imaging (MRI) is the best imaging method for evaluating ischemic/embolic events of central nervous system.


Subject(s)
Humans , Endocarditis/diagnostic imaging , Endocarditis, Bacterial/diagnostic imaging , Heart Valve Prosthesis/adverse effects , Ultrasonography , Radiopharmaceuticals , Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography
3.
Journal of Veterinary Science ; : e45-2019.
Article in English | WPRIM | ID: wpr-758946

ABSTRACT

Unenhanced echocardiography (UE), commonly used in veterinary practice, is limited by left ventricular (LV) foreshortening and observer dependency. Contrast echocardiography (CE) was used to compare two-dimensional (2D) LV measurements made using UE and 256-row multi-detector computed tomography (MDCT) as a reference standard. Seven healthy beagle dogs were evaluated in this study. Measurements obtained using CE, including LV wall thickness, internal diameter, and longitudinal and transverse length, were significantly greater than those obtained using UE. Measurements of LV internal dimension in diastole (LVIDd) and systole (LVIDs) were significantly larger with CE compared UE. Regardless of the cardiac cycle, LV longitudinal (LVLd and LVLs) and transverse diameter (LVTDd and LVTDs) measurements were significantly different with CE and approximated values from MDCT. Among automatically calculated parameters, LV end-systolic volume and the relative wall thickness were significantly different between UE and CE. In CE, the correlation coefficients of 4 major parameters (r = 0.87 in LVIDd; 0.91 in LVIDs; 0.87 in LVLd; and 0.81 in LVLs) showed higher values compared to the UE (r = 0.68 in LVIDd, 0.71 in LVIDs, 0.69 in LVLd, and 0.35 in LVLs). Inter-observer agreement was highest for MDCT and higher for CE than UE. In conclusion, CE is more accurate and reproducible than UE in assessing 2D LV measurements and can overcome the limitations of UE including LV foreshortening and high observer dependency.


Subject(s)
Animals , Dogs , Diastole , Echocardiography , Multidetector Computed Tomography , Systole
4.
Korean Journal of Nuclear Medicine ; : 301-312, 2019.
Article in English | WPRIM | ID: wpr-786494

ABSTRACT

Recent clinical trials have demonstrated the values of cardiac computed tomography (CT) in the initial evaluation of stable chest pain which led to drastic changes in the National Institute for Health and Care Excellence (NICE) guidelines in 2016. According to the updated NICE guidelines, cardiac CT should be performed as the initial cardiac testing in stable chest pain regardless of pre-test probability (PTP) of coronary artery disease (CAD). As a result, cardiac CT is now considered as a validated gatekeeper for assessing stable chest pain, which precedes all the functional studies including nuclear myocardial perfusion imaging (MPI). Nuclear MPI, in contrast, has been assigned as one of the second-line studies, which is inevitably dependent on the results of cardiac CT. However, nuclear MPI has genuine values in the diagnosis, treatment decision, and prognostic stratification of stable chest pain, which cannot be replaced by cardiac CT. In this review, the updated NICE guidelines and related cardiac CT trials will be critically reviewed from the view of nuclear physicians and the exceptional values of nuclear MPI will be described along with the future perspectives.


Subject(s)
Cardiology , Chest Pain , Coronary Artery Disease , Diagnosis , Myocardial Perfusion Imaging , Thorax
5.
The Korean Journal of Thoracic and Cardiovascular Surgery ; : 71-77, 2017.
Article in English | WPRIM | ID: wpr-169852

ABSTRACT

BACKGROUND: Cardiac computed tomography (CT) has emerged as an alternative to magnetic resonance imaging (MRI) for ventricular volumetry. However, the clinical use of cardiac CT requires external validation. METHODS: Both cardiac CT and MRI were performed prior to pulmonary valve implantation (PVI) in 11 patients (median age, 19 years) who had undergone total correction of tetralogy of Fallot during infancy. The simplified contouring method (MRI) and semiautomatic 3-dimensional region-growing method (CT) were used to measure ventricular volumes. RESULTS: All volumetric indices measured by CT and MRI generally correlated well with each other, except for the left ventricular end-systolic volume index (LV-ESVI), which showed the following correlations with the other indices: the right ventricular end-diastolic volume index (RV-EDVI) (r=0.88, p<0.001), the right ventricular end-systolic volume index (RV-ESVI) (r=0.84, p=0.001), the left ventricular end-diastolic volume index (LV-EDVI) (r=0.90, p=0.001), and the LV-ESVI (r=0.55, p=0.079). While the EDVIs measured by CT were significantly larger than those measured by MRI (median RV-EDVI: 197 mL/m² vs. 175 mL/m², p=0.008; median LV-EDVI: 94 mL/m² vs. 92 mL/m², p=0.026), no significant differences were found for the RV-ESVI or LV-ESVI. CONCLUSION: The EDVIs measured by cardiac CT were greater than those measured by MRI, whereas the ESVIs measured by CT and MRI were comparable. The volumetric characteristics of these 2 diagnostic modalities should be taken into account when indications for late PVI after tetralogy of Fallot repair are assessed.


Subject(s)
Humans , Heart Defects, Congenital , Magnetic Resonance Imaging , Methods , Pulmonary Valve , Stroke Volume , Tetralogy of Fallot
6.
Korean Journal of Radiology ; : 773-785, 2017.
Article in English | WPRIM | ID: wpr-139815

ABSTRACT

The role of cardiac computed tomography (CT) for evaluating the mitral valve (MV) has been limited since echocardiography is the main method of evaluation. However, recent advances in cardiac CT have enable detailed evaluation of the anatomy and geometry of the MV. We describe assessments of the anatomy and coaptation geometric parameters of normal MVs, and also review repair of diseased/damaged MV. We also discuss pre- and post-surgical imaging of MV pathology using cardiac CT and various CT images. We found that cardiac CT could be used as an alternative imaging modality to echocardiography for pre-operative MV evaluation and to predict clinical outcomes following repair.


Subject(s)
Echocardiography , Heart Valves , Methods , Mitral Valve Insufficiency , Mitral Valve , Pathology
7.
Korean Journal of Radiology ; : 773-785, 2017.
Article in English | WPRIM | ID: wpr-139814

ABSTRACT

The role of cardiac computed tomography (CT) for evaluating the mitral valve (MV) has been limited since echocardiography is the main method of evaluation. However, recent advances in cardiac CT have enable detailed evaluation of the anatomy and geometry of the MV. We describe assessments of the anatomy and coaptation geometric parameters of normal MVs, and also review repair of diseased/damaged MV. We also discuss pre- and post-surgical imaging of MV pathology using cardiac CT and various CT images. We found that cardiac CT could be used as an alternative imaging modality to echocardiography for pre-operative MV evaluation and to predict clinical outcomes following repair.


Subject(s)
Echocardiography , Heart Valves , Methods , Mitral Valve Insufficiency , Mitral Valve , Pathology
8.
Arch. cardiol. Méx ; 85(1): 63-67, ene.-mar. 2015. ilus
Article in Spanish | LILACS | ID: lil-746438

ABSTRACT

En los últimos años hemos sido testigos del continuo desarrollo de las técnicas de imagen en cardiología. Entre ellas, la tomografía computarizada cardiaca, técnica emergente y en continua evolución. Con la posibilidad actual de realizar estudios con muy baja radiación se han ampliado sus indicaciones más allá de la coronariografía no invasiva. En el presente trabajo de revisión repasamos las novedades técnicas de la tomografía computarizada cardiaca así como sus nuevas aplicaciones.


During the last years we have witnessed an increasing development of imaging techniques applied in Cardiology. Among them, cardiac computed tomography is an emerging and evolving technique. With the current possibility of very low radiation studies, the applications have expanded and go further coronariography In the present article we review the technical developments of cardiac computed tomography and its new applications.


Subject(s)
Humans , Cardiac Imaging Techniques/methods , Tomography, X-Ray Computed
9.
Korean Journal of Radiology ; : 251-285, 2015.
Article in English | WPRIM | ID: wpr-183065

ABSTRACT

The development of cardiac CT has provided a non-invasive alternative to echocardiography, exercise electrocardiogram, and invasive angiography and cardiac CT continues to develop at an exponential speed even now. The appropriate use of cardiac CT may lead to improvements in the medical performances of physicians and can reduce medical costs which eventually contribute to better public health. However, until now, there has been no guideline regarding the appropriate use of cardiac CT in Korea. We intend to provide guidelines for the appropriate use of cardiac CT in heart diseases based on scientific data. The purpose of this guideline is to assist clinicians and other health professionals in the use of cardiac CT for diagnosis and treatment of heart diseases, especially in patients at high risk or suspected of heart disease.


Subject(s)
Humans , Chest Pain/diagnosis , Exercise , Heart/diagnostic imaging , Heart Diseases/diagnosis , Republic of Korea , Tomography, X-Ray Computed/instrumentation
10.
Korean Journal of Radiology ; : 4-11, 2014.
Article in English | WPRIM | ID: wpr-114863

ABSTRACT

Cardiac computed tomography (CT) has emerged as a noninvasive modality for the assessment of coronary artery disease (CAD), and has been rapidly integrated into clinical cares. CT has changed the traditional risk stratification based on clinical risk to image-based identification of patient risk. Cardiac CT, including coronary artery calcium score and coronary CT angiography, can provide prognostic information and is expected to improve risk stratification of CAD. Currently used conventional cardiac CT, provides accurate anatomic information but not functional significance of CAD, and it may not be sufficient to guide treatments such as revascularization. Recently, myocardial CT perfusion imaging, intracoronary luminal attenuation gradient, and CT-derived computed fractional flow reserve were developed to combine anatomical and functional data. Although at present, the diagnostic and prognostic value of these novel technologies needs to be evaluated further, it is expected that all-in-one cardiac CT can guide treatment and improve patient outcomes in the near future.


Subject(s)
Female , Humans , Male , Middle Aged , Coronary Angiography/methods , Coronary Artery Disease/physiopathology , Prognosis , Risk , Tomography, X-Ray Computed/methods
11.
Yonsei Medical Journal ; : 1104-1109, 2013.
Article in English | WPRIM | ID: wpr-198367

ABSTRACT

PURPOSE: For the successful completion of transcatheter closure of atrial septal defects with the Amplatzer septal occluder, shape of the defects should be considered prior to selecting the device. The purpose of this study is to evaluate the results of a transcatheter closure of oval shaped atrial septal defect. MATERIALS AND METHODS: From November 2009 until November 2011, cardiac computed tomography was performed on 69 patients who needed a transcatheter closure of atrial septal defect. We defined an oval shaped atrial septal defect as the ratio of the shortest diameter to the longest diameter 0.05). The differences between the device size to the longest diameter of the defect and the ratios of the device size to the longest diameter were significantly smaller in the ovoid group (1.8+/-2.8 vs. 3.7+/-2.6 and 1.1+/-0.1 vs. 1.2+/-0.2). CONCLUSION: Transcatheter closure of an oval shaped atrial septal defect was found to be safe with the smaller Amplatzer septal occluder device when compared with circular atrial septal defects.


Subject(s)
Humans , Middle Aged , Echocardiography , Heart Septal Defects, Atrial/pathology , Postoperative Complications , Republic of Korea , Retrospective Studies , Septal Occluder Device/adverse effects , Tomography, X-Ray Computed , Treatment Outcome
12.
Journal of Cardiovascular Ultrasound ; : 64-71, 2013.
Article in English | WPRIM | ID: wpr-59662

ABSTRACT

BACKGROUND: This study was to investigate the feasibility of real-time 3-dimensional echocardiography (RT3DE) for the analysis of biventricular ejection fractions and volume measurements in patients with cor pulmonale and the correlations of RT3DE results with 64-slice multi-detector cardiac computed tomography (64-MDCT) results. METHODS: This study included a total of 22 patients (59.3 +/- 16.6 years of age; 10 males and 12 females) who showed flattening or reverse curvature of the interventricular septum and severe pulmonary hypertension [mean right ventricular (RV) systolic pressure = 66.8 +/- 19.7 mmHg] on 2-dimensional transthoracic echocardiography due to cor pulmonale. Biventricular end-diastolic and end-systolic volumes were measured by RT3DE and 64-MDCT. The severity of D-shaped deformation was evaluated by using left ventricular (LV) eccentricity index (ratio of diameters parallel/perpendicular to the interventricular septum on parasternal short axis images of the papillary muscle level). RESULTS: There were moderate correlations between biventricular volumes measured by RT3DE and 64-MDCT except for LV end-systolic volume (59.8 +/- 17.1 vs. 73.2 +/- 20.2 mL, r = 0.652, p = 0.001 for LV end-diastolic volume; 30.6 +/- 9.1 vs. 30.8 +/- 12.5 mL, r = 0.361, p = 0.099 for LV end-systolic volume; 110.1 +/- 42.9 vs. 171.1 +/- 55.3 mL, r = 0.545, p = 0.009 for RV end-diastolic volume; and 80.9 +/- 35.0 vs. 128.7 +/- 45.1 mL, r = 0.549, p = 0.005 for RV end-systolic volume respectively). CONCLUSION: This study suggests that RT3DE may be a modest method for measuring distorted biventricular end-systolic and end-diastolic volumes in patients with cor pulmonale.


Subject(s)
Humans , Male , Axis, Cervical Vertebra , Blood Pressure , Echocardiography , Echocardiography, Three-Dimensional , Hypertension, Pulmonary , Papillary Muscles , Pulmonary Heart Disease
SELECTION OF CITATIONS
SEARCH DETAIL